Home » Product List » Enclosed Switching Power Supply » Meanwell 100W UL/cUL/CB/CE 24V (5V,7.5V,9V,12V,15V,48V) Single Output ,Miniature Switching Power Supply Nes-100-24
Product Details
Meanwell 100W UL/cUL/CB/CE 24V (5V,7.5V,9V,12V,15V,48V) Single Output ,Miniature Switching Power Supply Nes-100-24
| Packing: | 0.55kg; 30PCS/17.5kg/0.97cuft |
|---|---|
| Model NO.: | NES-100-5;NES-100-7.5;NES-100-9(12, 15, 24, 48) |
| Standard: | CE/EMC/ROHS |
| Productivity: | 200000PCS/Year |
| Unit Price: | Negotiable |
| Shipment Terms: | FOB |
| Payment Terms: | L/C,T/T,Western Union,Paypal |
| Minimum Order: | 50 Pieces |
| Price Valid Time: | From Dec 12,2011 To Oct 20,2012 |
| HS Code: | 8504401400 |
| Trademark: | MeanWell |
| Origin: | China |
| Certification: | CE |
| Warranty: | 2 Years |
| Output Type: | Single |
| Output Power: | 101 - 200W |
| Input Voltage: | Full Range |
| Voltage Regulating Mode: | Frequency Modulation Type |
| Starting Mode: | Self-excited Switching Power Supply |
| Connection Mode: | Series Switching Power Supply |
| Export Markets: | North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe |
Product Description
Meanwell 100W UL/cUL/CB/CE 24V(5V, 7.5V, 9V, 12V, 15V, 48V ) Single Output, Miniature Switching Power Supply NES-100-24
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
2 years warranty
| MODEL | NES-100-5 | NES-100-7.5 | NES-100-9 | NES-100-12 | NES-100-15 | NES-100-24 | NES-100-48 | |
| OUTPUT | DC VOLTAGE | 5V | 7.5V | 9V | 12V | 15V | 24V | 48V |
| RATED CURRENT | 20A | 13.6A | 11.2A | 8.5A | 7A | 4.5A | 2.3A | |
| CURRENTRANGE | 0 ~ 20A | 0 ~ 13.6A | 0 ~ 11.2A | 0 ~8.5A | 0 ~ 7A | 0 ~ 4.5A | 0 ~ 2.3A | |
| RATED POWER | 100W | 102W | 100.8W | 102W | 105W | 108W | 110.4W | |
| RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | |
| VOLTAGEADJ. RANGE | 4.75 ~ 5.5V | 7.13 ~ 8.3V | 8.55 ~ 9.9V | 11.4 ~ 13.2V | 14.25 ~ 16.5V | 22.8 ~ 26.4V | 45.6 ~ 52.8V | |
| VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
| LINE REGULATION Note.4 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
| LOAD REGULATION Note.5 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
| SETUP, RISE TIME | 500ms, 20ms/230VAC 500ms, 20ms/115VAC at ful l load | |||||||
| HOLD UP TIME (Typ.) | 30ms/230VAC 25ms/115VAC at ful l load | |||||||
| INPUT | VOLTAGERANGE | 85 ~ 132VAC / 176 ~ 264VAC selected by switch 248 ~ 373VDC | ||||||
| FREQUENCYRANGE | 47 ~ 63Hz | |||||||
| EFFICIENCY (Typ.) | 80% | 81% | 81% | 83% | 84% | 86% | 86% | |
| AC CURRENT (Typ.) | 2A/115VAC 1.2A/230VAC | |||||||
| INRUSH CURRENT (Typ.) | COLD START 36A | |||||||
| LEAKAGE CURRENT | <2mA / 240VAC | |||||||
|
PROTECTION (Note. 5) |
OVERLOAD | 105 ~ 150% rated output power | ||||||
| Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||||||||
| OVER VOLTAGE | 5.75 ~ 6.75V | 8.6 ~ 10.1V | 10.4 ~ 12.2V | 13.8 ~ 16.2V | 17.25 ~ 20.25V | 27.6 ~ 32.4V | 55.2 ~ 64.8V | |
| Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||||||||
| ENVIRONMENT | WORKING TEMP | -20~ +60C(Refer to "Derating Curve") | ||||||
| WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||
| STORAGE TEMP., HUMIDITY | -40~ +85C, 10~ 95% RH | |||||||
| TEMP. COEFFICIENT | ±0.03%/C (0 ~ 50C) | |||||||
| VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |||||||
|
SAFETY & EMC (Note 5) |
SAFETY STANDARDS | UL60950-1, TUV EN60950-1 approved | ||||||
| WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||||
| ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25C/ 70% RH | |||||||
| EMC EMISSION | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 | |||||||
| EMC IMMUNITY | Compl iance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A | |||||||
| OTHERS | MTBF | 320.7Khrs min. MIL-HDBK-217F (25C) | ||||||
| DIMENSION | 159*97*38mm (L*W*H) | |||||||
| PACKING | 0.55Kg; 30pcs/17.5Kg/0.97CUFT | |||||||
| NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies |
|||||||
Inquiry Basket (