Home » Product List » DC-DC Converter » Meanwell 150W CB/CE 12/24V Single Output DC-DC Converter Enclosed Type SD-150
Product Details
Meanwell 150W CB/CE 12/24V Single Output DC-DC Converter Enclosed Type SD-150
| Packing: | 0.86kg; 16PCS/14.5kg/0.95cuft |
|---|---|
| Model NO.: | SD-150B-12;SD-150C-12;SD-150D-12;SD-150B(C, D)-24 |
| Standard: | UL/EMC/ROHS |
| Productivity: | 200000PCS/Year |
| Unit Price: | Negotiable |
| Shipment Terms: | FOB |
| Payment Terms: | L/C,T/T,Western Union,Paypal |
| Minimum Order: | 1 Boxes |
| Price Valid Time: | From Nov 21,2011 To Oct 01,2012 |
| HS Code: | 8504401400 |
| Trademark: | MeanWell |
| Origin: | China |
| Certification: | CE |
| Warranty: | 2 Years |
| Output Type: | Single |
| Output Power: | 101 - 200W |
| Input Voltage: | Full Range |
| Voltage Regulating Mode: | Frequency Modulation Type |
| Starting Mode: | Self-excited Switching Power Supply |
| Connection Mode: | Series Switching Power Supply |
| Export Markets: | North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe |
Product Description
Meanwell 150W CB/CE 12/24V Single Output DC-DC Converter Enclosed Type SD-150
2: 1 wide input range
Protections: Short circuit / Overload / Over voltage
1500VAC I/O isolation
Built-in EMI filter, low ripple noise
100% full load burn-in test
24V and 48V input voltage design refer to LVD
Low cost
High reliability
2 years warranty
| MODEL | SD-150B-12 | SD-150C-12 | SD-150D-12 | SD-150B-24 | SD-150C-24 | SD-150D-24 | ||
| OUTPUT | DC VOLTAGE | 12V | 24V | |||||
| RATED CURRENT | 12.5A | 6.3A | ||||||
| CURRENTRANGE | 0 ~ 12.5A | 0 ~ 6.3A | ||||||
| RATED POWER | 120W | 150W | ||||||
| RIPPLE & NOISE (max. ) Note. 2 | 120mVp-p | 150mVp-p | ||||||
| VOLTAGE ADJ. RANGE | 11 ~ 16VDC | 23 ~ 30VDC | ||||||
| VOLTAGE TOLERANCE Note. 3 | ± 1.0% | ± 1.0% | ||||||
| LINE REGULATION | ± 0.5% | ± 0.3% | ||||||
| LOAD REGULATION | ± 0.5% | ± 0.3% | ||||||
| SETUP, RISE TIME | 2s, 50ms(only D mode) at full load | |||||||
| HOLD UP TIME (Typ. ) | 24ms(only D mode) at full load | |||||||
| INPUT | VOLTAGERANGE | B: 19 ~ 36VDC C: 36 ~ 72VDC D: 72 ~ 144VDC or 85 ~ 132VAC | ||||||
| FREQUENCY (Typ. ) | 75% | 77% | 79% | 77% | 80% | 82% | ||
| DC CURRENT (Typ. ) | 6.8A/24V | 3.4A/48V | 2.7A/96V | 6.8A/24V | 3.4A/48V | 2.7A/96V | ||
| INRUSH CURRENT (Typ. ) | D: 22.5A/96VDC | |||||||
| LEAKAGE CURRENT | < 0.75mA/120VAC(SD-100D) | |||||||
| PROTECTION | OVERLOAD | 105 ~ 135% rated output power | ||||||
| Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||||
| OVER VOLTAGE | 16.8V ~ 20V/10% LOAD | 31.5 ~ 37.5V/10% LOAD | ||||||
| Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||||
| ENVIRONMENT | WORKING TEMP | -10 ~ +60C(Refer to " Derating Curve" ) | ||||||
| WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||
| STORAGE TEMP., HUMIDITY | -20~ +85C, 10 ~ 95% RH | |||||||
| TEMP. COEFFICIENT | ± 0.03%/C (0 ~ 50C) | |||||||
| VIBRATION | 10 ~ 500Hz, 2G 10min. /1cycle, 60min. each along X, Y, Z axes | |||||||
|
SAFETY & EMC |
SAFETY STANDARDS | IEC60950-1 CB approved by TUV (for D type only) | ||||||
| WITHSTAND VOLTAGE | I/P-O/P: 1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | |||||||
| ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC / 25C/ 70% RH |
|||||||
| EMC EMISSION | Compliance to EN55022 (CISPR22) Class B | |||||||
| EMC IMMUNITY | Compliance to EN61000-4-2, 3, 4, 6, 8, EN55024, light industry level, criteria A | |||||||
| OTHERS | MTBF | 296.2K hrs min. (SD-150B) 289.9K hrs min. (SD-150C) 289K Hrs min. (SD-150D) MIL-HDBK-217F (25C ) | ||||||
| DIMENSION | 199*110*50mm (L*W*H) | |||||||
| PACKING | 0.86Kg; 16pcs/14.5Kg/0.95CUFT | |||||||
| NOTE |
1. All parameters NOT specially mentioned are measured at 24, 48, 96VDC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |
|||||||
Inquiry Basket (